Mitsubishi MOTION CONTROLLERS Q173DCPU Bedienerhandbuch Seite 164

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 252
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 163
4 - 19
4 INSTALLATION AND WIRING
4.2.3 Forced stop input cable
(1) Precautions for handling the forced stop input cable
• For connection or removal of the forced stop input cable, do it surely while
holding a forced stop input connector.
Tab
Motion CPU module
(2) Connection of the forced stop input cable
• For connection of a forced stop input cable to the Motion CPU module, connect
it surely to a forced stop input connector of Motion CPU module while holding a
connector. Be sure to insert it until it clicks.
(3) Removal of the forced stop input cable
• For removal of the forced stop input cable, push a tab and pull out the cable
while holding a connector.
POINTS
The following handling will damage the Motion CPU module or forced stop input
cable.
• Forced removal of the forced stop input cable from the CPU module.
• The forced stop input cable is twined other cables.
• Excessive power is applied at cable laying.
Wire the cable correctly.
Seitenansicht 163
1 2 ... 159 160 161 162 163 164 165 166 167 168 169 ... 251 252

Kommentare zu diesen Handbüchern

Keine Kommentare