2 SYSTEM CONFIGURATION
(c) Wiring example for external pulse input to safety signal module.
The wiring diagram for external pulse input signal and safety signal module
shows below.
Safety module performs the safety diagnostics of external pulse generator,
therefore you need to wire them so that external pulse generator is supplied
power by the safety signal module, and the generated pulse becomes input
signal of safety signal module.
(Y0B)
(X12)
(X13)
(Y0B)
(X12)
(X13)
Power supply to the
external pulse
(Output at SLS/SOS
executing)
1B01
1B09
1A18
1A17
1A01
2B01
2B09
2A18
2A17
2A01
Motion CPU side
PLC CPU side
Safety signal module
(Q173DSXY)
External pulse
input signal (Phase A)
External pulse
input signal (Phase B)
External pulse
input signal (Phase A)
External pulse
input signal (Phase B)
External pulse
input signal (Phase A)
External pulse
input signal (Phase B)
(Note): Only SOS function use
Power supply to the
external pulse
(Output at SOS
executing)
24VDC