6 - 3
6 DRIVE MODULE
2) Simultaneous start
.......The simultaneous start axis No. and directions (forward/reverse) are
set by the JOG operation simultaneous start axis setting register
(D710 to D713)
(Note-3)
, and it is started by turning on the JOG
operation simultaneous start command flag (M2048)
(Note-3)
.
Virtual axis 1, 2 simultaneous program
[Virtual axis 1]
Mechanical system program
[Virtual axis 2]
Wait until PX000 and switching status
turn on, and axis 1, 2 start accept flag
turn off.
Virtual servo motor
Simultaneous start
PX001*M2044*!M2001*!M2002
D710=H0002
D712=H0001
D640L=K150000
D642L=K150000
SET M2048
P0
P0
PX000
RST M2048
JOG operation
JOG operation execution by
turning on the JOG operation
simultaneous start command
G20
G10
F10
When the 2 axes simultaneous start switch
(PX000) turn on, the following JOG operation
is executed with speed of 150000 [mm/min].
[PX000 : 1 axis reverse, 2 axes forward]
(Note) : Example of the above Motion SFC program is started using the automatic start or PLC program.
REMARK
(Note-1) : Refer to Section "6.21 JOG Operation" of the "Q173DCPU/Q172DCPU
Motion controller (SV13/SV22) Programming Manual (REAL MODE)" for
details of the JOG operation.
(Note-2) : Refer to Section 4.1.4 (3) for details of the forward/reverse rotation JOG
start commands.
(Note-3) : Refer to Section 4.2.8 (2) for details of the JOG operation simultaneous
start axis setting registers, and Section 4.1.7 (14) for details of the JOG
operation simultaneous start command.