Mitsubishi F940GOT-LWD-E Technical Information Seite 72

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 330
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 71
Graphic Operation Terminal F940GOT HPP Mode 4
4-12
4.4 DEVICE MONITOR
The ON/OFF status and the set value/current value of arbitrary devices in the PLC can be
monitored. In addition, the ON/OFF status can be forcedly set to ON/OFF and the set values/
current values can be changed.
When "DEVICE MONITOR" is selected on the HPP MODE
screen, the DEVICE MONITOR screen shown on the left is
displayed.
Function keys are provided at the bottom of the screen. Each
function key is actuated when touched.
DEVICE :Allows to specify the device No. to be monitored.
ON/OFF :Turns ON/OFF forcedly the specified device.
SET :Executes change of the current value/set value.
COMMENT:Changes over the monitor display.
4.4.1 Device/comment monitor
Symbols such as X and Y and comments can be displayed for monitoring. Comments can be
created using the screen creation software FX-PCS-DU/WIN-E.
Number of devices monitored and displayed on the screen
u
uu
u
Basic operation
Bit device Word device
14 devices/screen
7 devices/screen
(3 devices/screen for timers and counters)
[ DEVICE MONITOR ] END
[ DEVICE MONITOR ]
DEVICE ON OFF
SET
COMMENT
DEC/HEX
The HPP MODE
screen is displayed.
DEVICE
Enter a
device
symbol.
Device
symbol
ENT
Monitor a
consecutive device.
Move the cursor to a
device which has been
already registered.
M 100
CDEFCLR
89
ENT
B
4567
0123
A
XYMSCLR
TC
ENT
D32
ZV
D16
When the DEVICE key is pressed,
the device symbol list is displayed
as shown on the left.
Paragraph 4.4
Device
symbol
Seitenansicht 71
1 2 ... 67 68 69 70 71 72 73 74 75 76 77 ... 329 330