Mitsubishi RS232/485/LAN Serial Communication Control Handbuch Seite 142

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 349
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 141
Chapter2 Connection to a PLC
2-142
(*3) Address selection rule is as follows.
Standard device address format of WindO/I-NV2
B
25525515
Example
MicroLogix1200 Address --- B
10:123/
WindO/I-NV2 Address --- B
1012305
3 digits File number
2 di
g
its Bit number
3 di
g
its Element number
Allen-Bradley device address format
B
255
:
255
/15
3 digits File number
2 di
g
its Bit number
3 di
g
its Element number
(*4)
Address selection rule is as follows.
Standard device address format of WindO/I-NV2
TEN
255255
Example
MicroLogix1200 Address --- T
12:123/EN
WindO/I-NV2 Address --- TEN
12123
3 di
its Element number
3 di
g
its File number
Allen-Bradley device address format
TEN
255
:
255
3 di
g
its Element number
3 di
g
its File number
Seitenansicht 141
1 2 ... 137 138 139 140 141 142 143 144 145 146 147 ... 348 349

Kommentare zu diesen Handbüchern

Keine Kommentare