Safety measures
A dielectric fluid temperature detector, fluid level detector,
abnormal machining detector and automatic fire extinguisher,
standard equipment, and a flame-resistant metal hose is used.
Following legal ordinances, a tank which has passed a water
leakage test is used (for tank capacities less than 2,000 ,
tanks which have passed a voluntary water leakage test). Note
that the safety devices must be periodically inspected. Refer to
the instruction manual (safety manual) when using the EDM.
When heat is detected, a light-
water solution is automatically
sprayed to extinguish the fire.
Machining also stops
automatically at this time.
A separate 100VAC power
supply is required for the
automatic fire extinguisher.
Automatic fire extinguisher
Machining is
automatically stopped
when the dielectric
fluid temperature
reaches approx. 
60, or when the
fluid level drops
during machining.
Dielectric fluid 
temperature and fluid 
level detector
Certificate of 
voluntary water 
leakage test 
acceptance
Preparation for Machine Installation Precautions
Selecting the power facility capacity
Selecting the power input cable size and input power voltage
No-fuse breaker and earth-leakage breaker
Preventing fires and accidents with EDMs
Cautions
Ensure that the upper part of the workpiece is submerged by
50mm (1.97in) or more (FP60EA, FP60MA, FP80V) or
100mm (3.94in) or more (FP100EA, FP120V) from the
surface of the dielectric fluid
Never conduct spray machining as there is a risk of fire
Do not use equipment that produces heat or sparks such as
heating systems, welding machines, or grinding machinery
near the EDM
Always keep the area clean and tidy, and do not store
flammable materials near the EDM
Install an extra fire extinguisher in addition to the automatic
fire extinguisher enclosed with the EDM
Ensure that the area is sufficiently ventilated
Monitoring automatic operation : For safety purposes, make
sure an operator is always present during operation, even if
various safety devices are equipped, so that appropriate
actions can be taken
Nozzle
Shank
Tool electrode
Lead wire
Dielectric fluid
Electric discharge between tool
electrode and jet nozzle.
Electric discharge between lead
wire having broken insulated
coating and workpiece clamp.
Machining of a workpiece that
is too tall for the working tank.
Machining with sufficient room
in the working tank but not
enough dielectric fluid.
Electric discharge between
tool electrode and shank
because of tool electrode
and shank dislocation.
Electric discharge between tool
electrode and workpiece clamp.
Case in which electric discharge
occurs in an unexpected section
and very close to the fluid surface.
Clamp
Never attempt the following operation methods. These are extremely hazardous.
W
W
W
W
Before installing an EDM, ensure that sufficient power capacity can be supplied to meet the total power input requirements. The total
power input requirements include the power for the main unit and accessories (options).
When selecting a no-fuse breaker or earth-leakage breaker for the
primary side of the EDM, calculate the total facility capacity, and
select the breaker using the following table as a reference. The
breakers in the following table allow for the rush current of the
transformer in the power supply panel.
The following table is a guide for calculating the
appropriate power cable size to use based on total
capacity.
The cable size should be sufficient to allow some leeway.
To prevent malfunctions caused by the external noise from
control units, a filter is installed on the power supply input. By
grounding one end of this filter, an earth-leakage current of
approx. 30 to 40mA passes through this filter. If a highly
sensitive earth-leakage breaker (sensitivity current 30mA) is
installed, malfunctions could occur. Thus, a medium sensitivity
earth-leakage breaker (sensitivity current 100 to 200mA) is
recommended for the EDM. Class C grounding (grounding
resistance 10Ω or less) is recommended for the EDM. If Class
C grounding is provided, even if the sensitivity current is
200mA, the contact voltage will be 2V or less, and no
problems will occur in preventing electric shock (application of
tolerable contact current Class 2, 25V or less).
EDM power supplies use the latest electronics technologies. Any large
fluctuation in the voltage can cause an EDM to deviate from its
optimum working conditions, and cause a reduction in efficiency.
Although fluctuations within approx. ±5% of the rated voltage will not
cause a problem, an automatic voltage regulator (AVR) should be used
to stabilize fluctuations of ±10% or more that last for a long period of
time (e.g., operating the EDM at 180V when rated voltage is 200V).
Harmonic distortion in the power supply could affect machining
operation even when there is no voltage fluctuation. If such a problem
occurs, avoid use near equipment that generates harmonic distortion,
or provide measures such as a line filter.
Facility capacity
Total power input
(Machine input + power supply input + dielectric fluid temperature control unit input)
Total facility capacity
Total facility capacity Cable size
No-fuse breaker
Earth-leakage breaker
Precautions for selecting earth-leakage breakers
Stabilizing the power supply
Harmonic distortion
Control unit
Machine body
47 48
Product Line-up
Machining Samples
Total Solutions
Machine Specifications
and Options
Advance Series
Functions and Features
EA Series Functions
and Features
Advance Series
Product Introduction
MA, EA Series
Product Introduction
Advance Control Unit
Tooling
64-bit Control Unit
Power Supply/Control
Specifications
Preparation for
Machine Installation
Precautions
Seitenansicht 24
1 2 ... 20 21 22 23 24 25 26 27

Kommentare zu diesen Handbüchern

Keine Kommentare