Mitsubishi FDTC25VD Bedienungsanleitung Seite 12

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 34
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 11
-
11
-
'10 • SR-T-091D
A
RWA000Z 231
Model
Item
SRR25ZJ-S
Indoor unit SRR25ZJ-S Outdoor unit SRC25ZJX-S
Cooling capacity (1) W 2500 ( 900 (Min.)
~
3200 (Max.))
Heating capacity (1) W 3400 ( 900 (Min.)
~
4700 (Max.))
Power supply 1 Phase, 220
~
240 V, 50Hz
Operation
data (1)
Power
consumption
Cooling
kW
0.580 ( 0.19
~
0.82 )
Heating 0.750 ( 0.23
~
1.20 )
Running
current
Cooling
A
2.9 / 2.8 / 2.7 (220/ 230/ 240 V)
Heating 3.7 / 3.6 / 3.4 (220/ 230/ 240 V)
Inrush current 3.7 / 3.6 / 3.4 (220/ 230/ 240 V)
COP
Cooling 4.31
Heating 4.53
Noise
level
Cooling
Sound level dB(A) Hi : 40 Me
: 35 Lo : 29 47
Power level dB 54 60
Heating
Sound level dB(A) Hi: 41 Me: 38 Lo: 31 47
Power level dB 55 60
Exterior dimensions (Height x Width x Depth) mm 230 x 740 x 455 595 x 780 x 290
Exterior appearance
(Munsell color)
Stucco white
( 4.2Y 7.5/1.1 ) near equivalent
Net weight kg 22 38
Refrigerant
equipment
Compressor type & Q'ty RM-B5077MDE1 (Rotary type) x 1
Motor (Starting method) kW 0.75 (Line starting)
Refrigerant oil 0.35 (DIAMOND FREEZE MA68)
Refrigerant (3) kg R410A 1.2 ( Pre-Charged up to the piping length of 15m )
Heat exchanger Louver fins & inner grooved tubing M fins & inner grooved tubing
Refrigerant control Capillary tubes + Electronic expansion valve
Deice control Microcomputer control
Air handling
equipment
Fan type & Q'ty Centrifugal fan x 2 Propeller fan x 1
Motor W 51 24
Air flow
Cooling
CMM
Hi : 8.5 Me : 7.0 Lo : 5.0 29.5
Heating Hi : 10.0 Me : 9.0 Lo : 6.5 27.0
Fresh air intake Not possible
Air filter, Quality / Quantity Polypropylene net x 1
Shock & vibration absorber Cushion rubber (for compressor)
Electric heater
Operation
control
Operation switch Wireless-Remote control
Room temperature control Microcomputer thermostat
Operation Display
RUN : Green, TIMER : Yellow,
HI POWER : Green, ECONO : Green
Safety devices
Compressor overheat protection, Overcurrent protection, Drain error protection
Frost protection, Serial signal error protection, Indoor fan motor error protection,
Heating overload protection( High pressure control ), Cooling overload protection
Installation
data
Refrigerant piping size (O.D) mm Liquid line :
φ
6.35 (1/4") Gas line :
φ
9.52 (3/8")
Connecting method Flare connecting
Attached length of piping m
Insulation for piping Necessary (Both sides), independent
Refrigerant line (one way) length
m
Max. 15
Vertical height difference between
outdoor unit and indoor unit
Max. 10 (Outdoor unit is higher)
Max. 10 (Outdoor unit is lower)
Drain hose Connectable (VP16)
Power cable
Recommended breaker size A 16
Connection wiring
Size x Core number 1.5mm
2
x 4 cores (Including earth cable)
Connecting method Terminal block (Screw fixing type)
Accessories (included)
Mounting kit
Optional parts Wired remote control, Interface kit (SC-BIKN-E)
Note (1) The data are measured at the following conditions.
Item
Operation
Indoor air temperature Outdoor air temperature
Standards
DB WB DB WB
Cooling 27˚C 19˚C 35˚C 24˚C
ISO-T1, JIS C 9612
Heating 20˚C 7˚C 6˚C
(2) This air-conditioner is manufactured and tested in conformity with the ISO.
(3) The operation data are applied to the 220/230/240V districts respectively.
(4) The refrigerant quantity to be charged includes the refrigerant in 15m connecting piping.
(Purging is not required even for the short piping.)
The pipe length is 7.5m.
Adapted to RoHS directive
(3) Ceiling concealed type (SRR)
Downloaded from AC-Manual.com Manuals
Seitenansicht 11
1 2 ... 7 8 9 10 11 12 13 14 15 16 17 ... 33 34

Kommentare zu diesen Handbüchern

Keine Kommentare