How to monitor 32-bit integral number data
When the operation result of the multiplication instruction is outside the range from 0 to 32,767, the
result cannot be displayed properly even though the number is regarded as 16-bit integral number and
the contents of the lower register are monitored in ladder.
To monitor those numbers properly, follow the procedures below.
• Click the Display Format
button on the Device/Buffer Memory Batch Monitor dialog box and
select "32bit Integer" of "Display".
Click the OK
button.
The data is monitored properly.