Mitsubishi SRK20HG Bedienungsanleitung Seite 2

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 4
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 1
CONSTANT SPEED MODEL
5m
15m
Maximum height difference
Maximum pipe length
Refrigerant pipe length
Heat Pump
SRK20HG
SRK28HG
SRK40HG
SRC20HG
SRC28HG
SRC40HG
SRC52HE-2
SRC63HE-2
SRC71HE-2
CFD (computational fluid dynamics), used in blade shape design
of jet engines, has been applied to the design of air channels in air
conditioners to develop the ideal air channel system (air
circulation). The airflow of the jets created in this system enable a
large volume of air to be blown with minimum power
consumption, yet the air flow is uniform, quiet and reaches points a
long distance from the blower.
Old typeNew type
Colors in the figure show the air speed.
Slow Fast
We used the same aerodynamic analysis technology as
used in developing jet engines.
Aircraft technology was used in the design
of the air conditioner’s airflow system
The air conditioner main body employs
a tourmaline-coatedsheet.Thesheet
generates negative ions around the clock.
Even when the air conditioner is not
running, it generates as many negative ions
(2,500– 3,000/cc) as in a forest, stream or
fall does, allowing you to experience them
without incurring any electrical charges.
Generates the same amount of negative ions as a forest environment
“Self clean operation” is operated
for 2 hours after the unit has stopped
its normal operation.
The indoor unit is dried up and the
growth of mold is restrained. Users
can select whether this mode is
utilized or not.
Stop run
2hrs
Normal
operation
Clean
operation
Shuts off automatically
Situation of mold after one week
Fungal mycelia
expand.
When you don’t execute “Self Clean Operation”
The spore of mold
doesn't germinate.
When you execute “Self Clean Operation”
Always keeping the indoor unit clean
Coupling
Cell wall
Filter fiber
Enzyme
Enzyme
Bacterium
Powerful
sterilizing effect
Enzyme's sterilizing mechanism
Airflow
Conventional Filter Enzyme Filter
Analysis Zone
Analysis Zone
Analysis Zone
First in the world
Enzymes used in these filters are naturally occurring lytic enzymes.
The lytic enzymes attack cell walls of microorganisms trapped on a
filter and destroy them and doing so, have a powerful sterilizing
which will effect decrease the number of molds and bacteria
Natural Enzyme Filter will clean and sanitize air passing through it
to keep air in the room clean and safe.
The first release in this range of the enzyme-sterilizing filter
Sure to destroy fungi and bacteria, also effective on viruses and
allergenic compounds (Cat hair, dust mite, pollen etc.)
It will keep the air fresh by
deodorizing the molecules
causing odor. Its deodorizing
power can be restored by
washing with water and
drying under the sun, as such
it is a Recycling deodorizing
filter capable of repeat use.
The deodorizing ability of this filter can be easily restored
simply by cleaning and exposing to the sunlight
The printed wiring board of the outdoor unit is coated by silicon.
It lasts long having a tolerance for humidity.
Long lasting
The blower fan has undergone anti-microbial treatment to resist
mold and germs, making the system clean and safe. Foul odors
and molds, etc. which can occur when an air conditioning system
is not in operation are prevented.
Anti-microbial specifications and design
will deliver cleanliness and safety
Fungal
mycelia
Spore
of mold
Spore
of mold
Comfortable Functions
Comfortable Air Flow Functions
Automatic Operation
The air conditioner automatically selects from among heating,
cooling and dry operations.
Three "Hot" System
This series offers three "hot" systems. "Hot start" allows the unit to
begin operating immediately, while the "hot spurt" fast-heating
system works to increase the temperature setting by two degrees.
The "hot keep" system is used during automatic defrosting or to
prevent the influx of cool air. These three operational control
systems help ensure comfortable and efficient heating.
On Timer
This facility enables the operation to start a little earlier, so that the
room approaches optimum temperature at ON time when the
operation is started by ON-TIMER.
Thus it will try to be at the temperature you want, when you want.
On Timer
24-hour On/Off Programmable Timer
By combining a start timer with a stop timer, you can register two
timer operations a day. Once set, timers will faithfully start or
stop the system at a specified time of the day repeatedly.
24h Timer
Memory Flap
While the flap is swinging, it can be stopped at any angle desired.
The flap returns to the position that it was in when operation last
Memory
SWING FLAP
Flap moves up and down continuously.
Up/Down Flap Swing
The UP/DOWN flap can be adjusted to the preferred operations
angle, ranging from horizontal to perpendicular.
UP/DOWN
Microcomputer-Operated Defrosting
This mode automatically eliminates frost, and helps minimize
excessive operation in other modes.
MC
When removing the air inlet
panel for internal cleaning or
others, open the grill by 65
degrees and then pull it to
this side.
Detachable Indoor Air Inlet Panel
The air inlet panel on the indoor unit opens and closes easily,
making filter cleaning simple. The suction panel can also be
removed.
Detachable
Self-Diagnostic Function
In the case that the air conditioner malfunctions, an internal
microcomputer automatically runs a self-diagnosis. (Inspection
and repair should be performed by authorized dealers.)
Diagnostic
Self
Auto Restart Function
Restart
Auto
Power blackout auto restart function is a function that records the
operational status of the air-conditioner immediately prior to it being
switched off by a power cut, and then automatically resumes
operations at that point after the power has been restored.
Back-up Switch
Back-up
Switch
On the main unit,there is a backup on/off switch, which is useful
when you can't use remote control, or batteries are flat.
Horizontal blowing
COOLING & DRY
Slant forward blowing
HEATING
Auto Flap Mode
Whatever the operating mode is, the unit automatically selects
the optimal angle.
Auto Flap
Luminas Button
With wireless “Luminas” remote controls that even “glow in the
dark”, it is possible to operate all desired functions of the unit
with the click of a button.
Luminas
24-hour ION
Tourmaline-coated sheet generates negative ions around the
clock. Even when the air conditioner is not running, it generates
as many negative ions as a forest, stream or fall does, allowing
you to experience them without incurring any electricity charges.
24h ION
Others
Economy Mode
Economy
The unit realizes effective energy saving operation, while still
keeping a comfortable cooling and heating condition.
Dry Operation
DRY
The unit dehumidifies the room by intermittent cooling operation.
Off Timer
OFF Timer
The unit stops automatically at the set time.
Sleep Mode
Sleep
The room temperature is automatically controlled during the set
sleep mode period, ensuring that room temperature will not get
too cold or too hot.
Convenience & Economy Functions
Maintenance & Prevention Functions
"HI POWER" Operation
The unit can operate continuously in "HI POWER" mode for 15
minutes. This mode is convenient to reach the desired
temperature quickly.
Thick line : moves quickly
Thin line : moves slowly
COOLING & DRY
HEATING
Thick line : moves quickly
Thin line : moves slowly
Air Scroll
The swing of the flap causes the air flow to spiral as it reaches
the floor, and breeze reaches all of a room.
Air Scroll
SRK52/63/71HE-2
Lateral swing
It sends a pleasant breeze to a wide range in the room by
swinging the louver to right and left automatically. Louver
angle can be fixed at any desired position.
Lateral
Swing
SRK52/63/71HE-2
SRK52HE-2
SRK63HE-2
SRK71HE-2
Item
Model
(Indoor unit/Outdoor unit)
Power source
Cooling capacity
Heating capacity
Cooling input
Heating input
COP (In cooling)
COP (In heating)
Cooling current
Heating current
Sound power level
(Indoor/Outdoor)
Sound pressure level
(Hi / Me / Lo)
Exterior dimensions
(HXWXD)
Net weight
Refrigerant piping
(Outer dimention)
Refrigerant
Clean filter
ISO-T1(JIS)
ISO-T1(JIS)
Cooling
Heating
Cooling(Indoor)
Heating(Indoor)
Indoor/Outdoor
Indoor/Outdoor
Liquid line
Gas line
kW
kW
kW
kW
A
A
dB(A)
dB(A)
dB(A)
dB(A)
mm
kg
mm(in)
1Phase, 220/230/240V, 50Hz
2.07
2.36
0.655
0.64
3.16
3.69
2.9/3.1/3.3
2.9/3.1/3.3
53/59
53/59
35/28/26
34/31/27
8.5/28
2.53
2.67
0.77
0.685
3.29
3.90
3.6/3.4/3.2
3.2/3.0/2.8
55/60
56/60
39/33/30
39/33/29
268X790X 199 / 540X 780X290
8.5/31
6.35 (1/4")
3.5
3.7
1.09
1.09
3.21
3.39
5.0/4.8/4.6
5.0/4.8/4.6
56/63
57/64
40/38/34
40/38/34
8.5/38
12.7 (1/2")
SRK/SRC20HG SRK/SRC28HG SRK/SRC40HG
SPECIFICATIONS
5.4
5.6
1.73
1.49
3.12
3.76
8.6/8.3/7.9
7.4/7.1/6.8
59/65
59/65
43/39/36
41/39/37
15/47
SRK/SRC52HE-2
6.1
6.3
2.17
1.83
2.81
3.44
10.8/10.4/9.9
9.1/8.7/8.4
59/65
60/65
44/40/37
42/40/38
15/48
6.35 (1/4")
15.88 (5/8")
SRK/SRC63HE-2
6.8
7.2
2.05
1.88
3.32
3.83
10.2/9.8/9.4
9.4/9.0/8.6
59/69
59/70
45/41/38
44/42/39
318X1098X 248 / 750X880X 340
15/63
SRK/SRC71HE-2
9.52 (3/8")
R22
Natural Enzyme FilterX1 Photocatalytic Washable Deodorizing FilterX1
318X1098X 248 / 640X850X 290
3
HOT
S
t
a
r
t
K
e
e
p
S
p
u
r
t
SRK-HG
HE-2
series
Seitenansicht 1
1 2 3 4

Kommentare zu diesen Handbüchern

Keine Kommentare