CONTENTS
1. TECHNICAL CHANGES
····································
2
2. PART NAMES AND FUNCTIONS
······················
3
3. SPECIFICATION
·················································
4
4. OUTLINES AND DIMENSIONS
·························
5
5. WIRING DIAGRAM
············································
6
6. REFRIGERANT SYSTEM DIAGRAM
················
7
7. PERFORMANCE CURVES
································
9
8. TROUBLESHOOTING
······································
11
9. DISASSEMBLY INSTRUCTIONS
····················
12
SPLIT-TYPE, AIR CONDITIONERS
MU-GD08ND-
MU-GD10ND-
MU-GD12ND-
C1
C1
C1
TM
Indoor unit service manual
MS-GD•ND Series (TBH014)
No. TBH016
SERVICE MANUAL
Wireless type
Models
OUTDOOR UNIT
NOTE:
• RoHS compliant products have <G> mark on the spec name plate.
PARTS CATALOG (TBB016)
MU-GD08ND-
C1
Seitenansicht 0
1 2 3 4 5 6 ... 19 20

Inhaltsverzeichnis

Seite 1 - SERVICE MANUAL

CONTENTS1. TECHNICAL CHANGES····································22. PART NAMES AND FUNCTIONS······················33. SPECIFICATION···················

Seite 2 - TECHNICAL CHANGES1

10 Both indoor and outdoor units are under the same temperature/humidity condition.OUTDOOR LOW PRESSURE AND OUTDOOR UNIT CURRENTCOOL operation Air f

Seite 3 - PART NAMES AND FUNCTIONS

118-2. Trouble criterion of main parts$$:INNER PROTECTORTROUBLESHOOTING88-1. Cautions on troubleshooting1. Before troubleshooting, check the following

Seite 4 - SPECIFICATION

12DISASSEMBLY INSTRUCTIONS9OPERATING PROCEDUREPHOTOSPhoto 11. Removing the cabinet(1) Remove the screws fixing the top panel. (See Photo 1.)(2) Remove

Seite 5 - OUTLINES AND DIMENSIONS

133. Removing the propeller and the outdoor fan motor(1) Remove the cabinet. (Refer to 1.)(2) Remove the propeller nut and the propeller.NOTE : Loose

Seite 6 - WIRING DIAGRAM

14OPERATING PROCEDURE PHOTOS4. Removing the compressor(1) Remove the cabinet. (Refer to 1.)(2) Remove the soundproof felt.(3) Remove the screws fixing

Seite 7 - REFRIGERANT SYSTEM DIAGRAM

152. Removing the electrical parts(1) Remove the service panel and the cabinet. (Refer to 1.)(2) Remove the following parts.•Compressor capacitor (C1)

Seite 8 - (MU-GD12ND

16PHOTOSOPERATING PROCEDURE3. Removing propeller and the outdoor fan motor(1) Remove the cabinet. (Refer to 1.)(2) Remove the propeller nut and remove

Seite 9 - PERFORMANCE CURVES7

17PHOTOSOPERATING PROCEDURE4. Removing the compressor(1) Remove the cabinet. (Refer to 1.)(2) Remove the relay panel.(3) Remove the soundproof felt.(4

Seite 12 - DISASSEMBLY INSTRUCTIONS

2TECHNICAL CHANGES1MU-A08ND- C2 = MU-GD08ND- C11. Compressor has been changed. (2R10S3R236A-6B = KS-098NARC)2. Outdoor fan motor has been changed. (

Seite 13 - OPERATING PROCEDURE PHOTOS

MITSUBISHI ELECTRIC CONSUMER PRODUCTS (THAILAND) CO., LTD.AMATA NAKORN INDUSTRIAL ESTATE 700/406 MOO 7, TAMBON DON HUA ROH, AMPHUR MUANG, CHONBURI 200

Seite 14

32PART NAMES AND FUNCTIONSAir outletDrain outletPipingDrain hose Air inlet(back and side)MU-C08VCMU-C10VCMU-C13VCMU-C18VC Air inlet(back and s

Seite 15 - MU-GD10ND MU-GD12ND

4SPECIFICATION3Outdoor modelMU-GD08ND - C1MU-GD10ND - C1MU-GD12ND - C1Function CoolingPower supplySingle phase220-230V, 60HzCapacityCapacity kW 2.2-2.

Seite 16 - OPERATING PROCEDURE

54OUTLINES AND DIMENSIONS20.86.4416.98255145.5Service panelService portAir outLiquid refrigerant pipe jointRefrigerant pipe (flared) ;6.35Gas refriger

Seite 17

6WIRING DIAGRAM5MU-C08VCMU-C10VCMU-C13VCMU-GD08NDMU-GD10ND

Seite 18

7MU-C18VCREFRIGERANT SYSTEM DIAGRAM6Refrigerant flow in coolingCapillary tubeX3.0 ' X 1.6 ' 650 CompressorStop valve(with service port)Stop

Seite 19

8MAX.REFRIGERANT PIPING LENGTHModel Piping size O.D : mmRefrigerant piping : mGasX9.52LiquidX6.352010MU-GD08ND-Max. lengthAMax. heightBMU-GD10ND-MU-GD

Seite 20

9PERFORMANCE CURVES7The standard data contained in these specifications apply only to the operation of the air conditioner under normal conditions.Sin