TSB–03–13–003
5. Gather the following reprogramming equipment:
Reprogramming Cartridge (red label)
MB991711
256 KBYTE IC Memory Card (red) MB991717
ROM Pack (red label) MB991701
Use the appropriate database listed below
“Engine Compartment/Control Module” Labels Part No. MSSF–024G–00
NOTE: Reprogramming cartridges memory cards,and ROM packs are available from SPX/OTC by
calling 1–888–727–6672.
IMPORTANT
Dealers must update ROM packs as needed, depending on vehicle repair requirements for PCM
software updates.
For instructions on updating ROM packs using MEDIC, and for current database information:
1) From the MEDIC Main Menu, select “MUT–II ROM Pack Re–write.”
2) Select “ROM Pack Information.”
For assistance with updating ROM packs using MEDIC, contact the MEDIC Hotline at
1–800–846–7575 .
When updating the ROM packs for this bulletin, use the following passwords:
Database Number
Password
RN02111 1532
RN02112 2532
RN02113 4632
RN02114 7932
6. Install the red label reprogramming cartridge to the MUT–II. Then install the 256 KBYTE red
memory card and the red label ROM pack. Use the ROM pack with the appropriate database
number.
7. Reconnect the MUT–II. Connect both the 16–pin and the 12–pin data link connectors.
8. Turn the ignition key to ON.
NOTE: If the MUT–II displays “Error No. 11,” request a replacement from Standard Register at
(877) 227–6115, option 1.
DO NOT DISTURB THE HARNESS CABLES OR CONNECTIONS. INTERRUPTION DURING THE
PROGRAMMING PROCESS COULD CAUSE THE PCM TO LOSE DATA OR PREVENT FUTURE
PCM REPROGRAMMING.
9. Select “MFI / ELC A/T”.
10. If either of the following messages display, STOP! Do not continue with this procedure:
a. If the PCM has already been reprogrammed, the MUT–II will display “This ECU has already
been reprogrammed.” Do not continue with this procedure.
CAUTION
Seitenansicht 1