Chapter 11 Measurement Functions
11-1. Injector-Type Fuel Consumption Measurement
11-1-1. Function Select
(1) Press Special function button on the STV Top Menu
(illustrated on 3-2), then select Measurement Functions
tab on the upper part of the screen.
Press Fuel consumption measurement (Injection)
button on this menu screen.
(2) Function Selection
Measurements in Real-time -- to 11-1-2.
Data Display -- to 11-1-3.
Analyze -- to 11-1-4.
Print out -- To print out the view graph.
Data storing -- To load the data, which is stored in a
removal disc, onto the PC.
11-1-2. Measurement in Real-time
(1) Preparations Prior to Measurement
Set the sampling interval, and select the displayed unit of
measurement by pressing the buttons.
If you wish to select display items, press button.
When the setting complete, press button.
Note:
The amount of recording time is proportional determined
by the length of the sampling interval.
(2) Entering and Recording Record Information
Enter your user name and the vehicle model type.
button starts the measurement process.