Mitsubishi F940GOT-LWD-E Handbuch

Stöbern Sie online oder laden Sie Handbuch nach Nein Mitsubishi F940GOT-LWD-E herunter. Mitsubishi F940GOT-LWD-E Hardware manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 1 - GOT series

GOT seriesHuman-Machine-InterfaceHardware ManualHandy Graphic Operation TerminalF940GOT132728JY992D86901-BMITSUBISHI ELECTRICArt.No.:2001 05 07MITSUBI

Seite 2

F940GOT Handy Seriesviii6. Diagnostics...6-16.1 Primly Check

Seite 3 - (F94*GOT-*BD-H-E)

Associated Manual ListsixAssociated Manual ListsFurther information can be found in the following manuals.¤: Indispensable manual¡: Either manual is n

Seite 4

F940GOT Handy Series Associated Manual ListsxMEMO

Seite 5

1 Introduction2 Specifications3 Installation and Wiring4 Creation of Operation Switch Name Sheet5 Maintenance6 DiagnosticsF940GOT Handy Series Introdu

Seite 6

F940GOT Handy Series Introduction 1

Seite 7 - Series (F94*GOT-*BD-H-E)

F940GOT Handy Series Introduction 11-11. Introduction1.1 IntroductionThe F940GOT Handy Series (hereafter called “Handy GOT”) is an all-in-one type han

Seite 8

F940GOT Handy Series Introduction 11-21.1.1 Product Components1) Operation switchesThese switches give direct commands to inputs on thePLC, when immed

Seite 9 - Table of Contents

F940GOT Handy Series Introduction 11-31.2 Product Lists1.2.1 Model NameThe model name of the handy graphic operation terminal is expressed as follows.

Seite 10 - F940GOT Handy Series

F940GOT Handy Series Introduction 11-41.3 Options1.3.1 External CableThese external cable containing independent wires for communications, DC power su

Seite 11 - Associated Manual Lists

F940GOT Handy Series Introduction 11-5• F9GT-HCAB5-150This cable connects a Q Series PLC or motion controller(with 6-pin MINI-DIN connector), and is e

Seite 12

Foreword• This manual contains text, diagrams and explanations which will guide the reader in thecorrect installation and operation of the F940GOT Han

Seite 13

F940GOT Handy Series Introduction 11-65) Screen design software6) FX-2PIF two-port interfaceThis interface offered as an option allows use of a Handy

Seite 14

F940GOT Handy Series Introduction 11-71.4 Dimensions and Each Part Name1.4.1 Each Part Name of Front Panel and DimensionsDimensions: mm (inches) MASS:

Seite 15 - 1. Introduction

F940GOT Handy Series Introduction 11-81.4.2 Rear facea) Metal hook for wall mountingOffered to mount the Handy GOT on a wall.b) Hand strapAdjustable l

Seite 16 - POW ER GRIP SW

1 Introduction2 Specifications3 Installation and Wiring4 Creation of Operation Switch Name Sheet5 Maintenance6 DiagnosticsF940GOT Handy Series Specif

Seite 17 - Table 1.1: Product Lists

F940GOT Handy Series Specifications 2

Seite 18 - 1.3 Options

F940GOT Handy Series Specifications 22-12. SpecificationsCautionDuring abnormal communication (including cable break) when monitor is executed within

Seite 19 - For power supply or

F940GOT Handy Series Specifications 22-22.1 General Specifications2.2 Power Supply SpecificationsTable 2.1: General SpecificationsItem SpecificationsO

Seite 20

F940GOT Handy Series Specifications 22-32.3 Screen Hardware Specifications2.4 Emergency and Operation Switch SpecificationsTable 2.3: Screen Hardware

Seite 21

F940GOT Handy Series Specifications 22-4MEMO

Seite 22

1 Introduction2 Specifications3 Installation and Wiring4 Creation of Operation Switch Name Sheet5 Maintenance6 DiagnosticsHandy GOT Handy Series Inst

Seite 23

iF940GOT Handy Series(F94*GOT-*BD-H-E)Hardware ManualManual number : JY992D86901Manual revision : BDate : March 2001F940GOT Handy Series

Seite 24

Handy GOT Handy Series Installation and Wiring 3

Seite 25 - 2. Specifications

Handy GOT Handy Series Installation and Wiring 33-13. Installation and WiringThis section describes installation of the Handy GOT and wiring of the po

Seite 26 - 2.1 General Specifications

Handy GOT Handy Series Installation and Wiring 33-23.1.2 Wall MountingWhen mounting the Handy GOT on a wall, use the metal hook provided on its rear f

Seite 27

Handy GOT Handy Series Installation and Wiring 33-33.2 Connection Configuration3.2.1 Connection to PLC by F940GOT-*BD-H-E (RS-422)Connection of Handy

Seite 28

Handy GOT Handy Series Installation and Wiring 33-43.2.2 Connection to PLC by F943GOT-*BD-H-E (RS-232C)Connection of the Handy GOT (F943GOT-*BD-H-E) t

Seite 29

Handy GOT Handy Series Installation and Wiring 33-53.2.3 Signal Allocation of Connector and Untied WiresThe signal allocation within connector and unt

Seite 30

Handy GOT Handy Series Installation and Wiring 33-63.3 Installation of External CableConnect an optional external cable to the Handy GOT main unit.*1

Seite 31 - Hand strap

Handy GOT Handy Series Installation and Wiring 33-72) Put the external cable through the hole “c)” in the Handy GOT main unit, and connect it to“e)” a

Seite 32 - G R IP S W

Handy GOT Handy Series Installation and Wiring 33-83.4 Processing Panel of Control Box or Cabinet3.4.1 Using F940GOT Handy1) Installing a connector on

Seite 33 - 3.2 Connection Configuration

Handy GOT Handy Series Installation and Wiring 33-92) Using F9GT-HCNBConnect an FX/A/QnA Series PLC using a F9GT-HCNB as shown below. Furtherinformati

Seite 34 - Caution for CE EMC:

F940GOT Handy Seriesii

Seite 35

Handy GOT Handy Series Installation and Wiring 33-103.4.2 Using F943GOT HandyInstalling a connector on the panel of control box or cabinetConnect a Q

Seite 36 - Table 3.2: External Cable

Handy GOT Handy Series Installation and Wiring 33-113.4.3 Appearance of Relay Cable1) F9GT-HCAB2-150 relay cable for FX Series (FX0, FX0S, FX0N, FX1S,

Seite 37 - ") or less

Handy GOT Handy Series Installation and Wiring 33-123.4.4 Mounting Connector of Relay CableWhen mounting the relay cable connector on the panel of a c

Seite 38 - Table 3.4: Relay Cable

Handy GOT Handy Series Installation and Wiring 33-133.5 Wiring of Power SupplyFurther information about operation switches and emergency switch can be

Seite 39 - Table 3.5: External Cable

Handy GOT Handy Series Installation and Wiring 33-14Handy GOT power is supplied from the PLC or an external power supply unit.The current consumption

Seite 40 - C ontorol box or cabinet

1 Introduction2 Specifications3 Installation and Wiring4 Creation of Operation Switch Name Sheet5 Maintenance6 DiagnosticsF940GOT Handy Series Creatio

Seite 41 - Table 3.7:

F940GOT Handy Series Creation of Operation Switch Name Sheet 4

Seite 42 - Panel cut size

F940GOT Handy Series Creation of Operation Switch Name Sheet 44-14. Creation of Operation Switch Name SheetThis paragraph describes how to create the

Seite 43 - Caution:

F940GOT Handy Series Creation of Operation Switch Name Sheet 44-24.2 Attachment of sheet1) Removing the operation switch coverInsert a screwdriver int

Seite 44

1 Introduction2 Specifications3 Installation and Wiring4 Creation of Operation Switch Name Sheet5 Maintenance6 DiagnosticsF940GOT Handy Series Mainten

Seite 45

FAX BACKMitsubishi has a world wide reputation for its efforts in continually developing and pushing backthe frontiers of industrial automation. What

Seite 46

F940GOT Handy Series Maintenance 5

Seite 47 - OHP sheet specification

F940GOT Handy Series Maintenance 55-15. MaintenanceCautions:• Correctly install the battery for memory backup. Never charge, disassemble, heat, burn o

Seite 48 - 4.2 Attachment of sheet

F940GOT Handy Series Maintenance 55-2MEMO

Seite 49

1 Introduction2 Specifications3 Installation and Wiring4 Creation of Operation Switch Name Sheet5 Maintenance6 DiagnosticsF940GOT Handy Series Diagnos

Seite 50

F940GOT Handy Series Diagnostics 6

Seite 51 - 5. Maintenance

F940GOT Handy Series Diagnostics 66-16. Diagnostics6.1 Primly Check1) Check “POWER LED”If the POWER LED is OFF, check cable(s), and check 24V DC power

Seite 52

F940GOT Handy Series Diagnostics 66-2MEMO

Seite 53

F940GOT Handy Series Diagnostics 66-3MEMO

Seite 54

F940GOT Handy Series Diagnostics 66-4MEMO

Seite 56

F940GOT Handy Seriesiv

Seite 57

MITSUBISHI ELECTRICEuropean RepresentativesHeadquartersWiener Straße 89A-2500 Baden+43 (0) 2252 / 85 55 20Phone:+43 (0) 2252 / 488 60Fax:GEVAAUSTRIAP

Seite 58

F940GOT Handy SeriesvGuidelines for the Safety of the User and Protection of the F940GOT Handy Series (F94*GOT-*BD-H-E)This manual provides informatio

Seite 59

F940GOT Handy Seriesvi• Under no circumstances will Mitsubishi Electric be liable or responsible for anyconsequential damage that may arise as a resul

Seite 60 - MITSUBISHI ELECTRIC

viiTable of ContentsGuideline for Safty....................vAssociated Manual Lists...

Kommentare zu diesen Handbüchern

Keine Kommentare