Seite 1 - REMOTE I/O UNIT

CNCFCU6-DX561CONNECTION AND MAINTENANCE MANUALBNP-B2302*(ENG)REMOTE I/O UNIT

Seite 2 - Precautions for Safety

3. INSTALLATION 3.2 Noise Countermeasures I-4 3.2 Noise Countermeasures 3.2.1 Connection of FG (Frame Ground) The frame should basically be grou

Seite 3 - CAUTION

3. INSTALLATION 3.2 Noise Countermeasures I-5 3.2.2 Shield Clamping of Cables (1) Cables requiring ground connection with lead wire The FG wire

Seite 4 - I. CONNECTION MANUAL

3. INSTALLATION 3.2 Noise Countermeasures I-6 3.2.3 Connecting Spark Killers Connect a spark killer on the coil or contact in parallel for noise

Seite 5 - II. MAINTENANCE MANUAL

3. INSTALLATION 3.3 Installation I-7 3.3 Installation Each unit is installed in the sealed structure cabinet as a principle. When installing int

Seite 6 - I. CONNECTION MANUAL

3. INSTALLATION 3.4 Mounting Conditions I-8 3.4 Mounting Conditions (1) Parts, highly susceptible to dust, are mounted with a high density insi

Seite 7 - 1. OUTLINE

4. SYSTEM CONNECTION 4.1 General System Diagram I-9 4. SYSTEM CONNECTION 4.1 General System Diagram FGSV1CF10CF11R000MC1 MC1MC1CF11 CF10AUX2EMGB

Seite 8 - 2. CONFIGURATION

5. CONNECTION OF UNIT 5.1 Names of Each Part I-10 5. CONNECTION OF UNIT The methods for connecting to each unit and device are briefly explained

Seite 9 - Power specifications

5. CONNECTION OF UNIT 5.2 Unit Connection System Diagram I-11 5.2 Unit Connection System Diagram F010 cableCF10 RIO1↑01CS1 CS2↑CF10Remote I/O un

Seite 10 - 3.2 Noise Countermeasures

5. CONNECTION OF UNIT 5.3 Connection of Base I/O Unit I-12 5.3 Connection of Base I/O Unit The RIO1 connector is used for connection to the base

Seite 11 - CF34CF33

5. CONNECTION OF UNIT 5.4 Connection of RIO Unit I-13 5.4 Connection of RIO Unit The RIO2 connector is used to connect several remote I/O units.

Seite 12

Precautions for Safety Always read the specifications issued by the machine maker, this manual, related manuals and enclosed documents before s

Seite 13 - 3.3 Installation

5. CONNECTION OF UNIT 5.5 Connection of Power Supply I-14 5.5 Connection of Power Supply Supply the 24VDC power supply for the control circuit t

Seite 14 - 3.4 Mounting Conditions

5. CONNECTION OF UNIT 5.6 Connection of Encoder Speed Signal I-15 5.6 Connection of Encoder Speed Signal Encoder ENC1/2 (Note) Refer to follo

Seite 15 - 4. SYSTEM CONNECTION

5. CONNECTION OF UNIT 5.6 Connection of Encoder Speed Signal I-16 [Outline of connection] GNDPC∗PC1kΩ1kΩ100ΩENC1/2Spindleamplifier [Signal ass

Seite 16 - 5. CONNECTION OF UNIT

5. CONNECTION OF UNIT 5.7 Connection of Machine Input/Output Signal I-17 5.7 Connection of Machine Input/Output Signal Input Output Number of oc

Seite 17

5. CONNECTION OF UNIT 5.7 Connection of Machine Input/Output Signal I-18 [Signal assignment table] DO-LDI-LDI-RDO-LDI-LRemote I/O unitR-TMRI02 DC

Seite 18 - RIO1RIO2 DCIN

5. CONNECTION OF UNIT 5.7 Connection of Machine Input/Output Signal I-19 [Outline of input circuit] The digital signal input circuit includes the

Seite 19 - 5.4 Connection of RIO Unit

5. CONNECTION OF UNIT 5.7 Connection of Machine Input/Output Signal I-20 [Outline of output circuit] The digital signal output circuit is a source

Seite 20 - Stabilized power supply

APPENDIX 1 UNIT OUTLINE DRAWINGS AND INSTALLATION DIMENSIONS I-21APPENDIX 1 UNIT OUTLINE DRAWINGS AND INSTALLATION DIMENSIONS 0123456789ABCDEFST

Seite 21 - ENC pin No

APPENDIX 2 LIST OF CONNECTOR SETS I-22APPENDIX 2 LIST OF CONNECTOR SETS Connector case (3M) 10230-52F0-008 × 2 pcs. Strain relief

Seite 22

APPENDIX 3 CABLE MANUFACTURING DRAWINGS I-23APPENDIX 3 CABLE MANUFACTURING DRAWING As a rule, most F/R cables used with this product are

Seite 23

CAUTION 1. Items related to noise Always treat the shield cables indicated in this manual with grounding measures such as cable clamps. Sep

Seite 24 - X RX TX RX * TX RX TX RX *

APPENDIX 3 CABLE MANUFACTURING DRAWINGS I-24<Cable type name table> Appendix No. Cable type Application Max. length Standard cable lengt

Seite 25

APPENDIX 3 CABLE MANUFACTURING DRAWINGS Appendix 3.1 FCUA-R000 Cable Manufacturing Drawing I-25Appendix 3.1 FCUA-R000 Cable Manufacturing Drawin

Seite 26

APPENDIX 3 CABLE MANUFACTURING DRAWINGS Appendix 3.2 FCUA-R211 Cable Manufacturing Drawing I-26Appendix 3.2 FCUA-R211 Cable Manufacturing Drawin

Seite 27 - DIMENSIONS

APPENDIX 3 CABLE MANUFACTURING DRAWING Appendix 3.3 FCUA-R220 Cable Manufacturing Drawing I-27Appendix 3.3 FCUA-R220 Cable Manufacturing Drawing

Seite 28

APPENDIX 3 CABLE MANUFACTURING DRAWING Appendix 3.4 R300 Cable Manufacturing Drawing I-28Appendix 3.4 R300 Cable Manufacturing Drawing Applicat

Seite 29 - Soldering iron

APPENDIX 3 CABLE MANUFACTURING DRAWING Appendix 3.5 R301 Cable Manufacturing Drawing I-29Appendix 3.5 R301 Cable Manufacturing Drawing Applicat

Seite 30

APPENDIX 3 CABLE MANUFACTURING DRAWING Appendix 3.6 R-TM Manufacturing Drawing I-30Appendix 3.6 R-TM Manufacturing Drawing Application: Termin

Seite 31

APPENDIX 4 PRECAUTIONS FOR COMPLYING WITH UL/c-UL STANDARDS I-31APPENDIX 4 PRECAUTIONS FOR COMPLYING WITH UL/c-UL STANDARDS Observe the followi

Seite 32 - Note (3)

II. MAINTENANCE MANUAL

Seite 33 - Note (1)

1. EXPLANATION OF MODULE FUNCTIONS 1.1 FX2N-80BMT-NC Card II-1 1. EXPLANATION OF MODULE FUNCTIONS 1.1 FX2N-80BMT-NC Card [Block diagram] RI

Seite 34 - Note (1) (1)

FCU6-DX561 CONNECTION AND MAITENANCE MANUAL CONTENTS I. CONNECTION MANUAL 1. OUTLINE ...

Seite 35

1. EXPLANATION OF MODULE FUNCTIONS 1.1 FX2N-80BMT-NC Card II-2 [Connector layout diagram] RIO2U:DI-RL:DI-LU:ENC2L:ENC1SW2DCINDO-LSW1PROG.PORTRIO1

Seite 36 - D-3 AM P

2. FAULT DIAGNOSIS 2.1 List of Unit LEDs II-3 2. FAULT DIAGNOSIS 2.1 List of Unit LEDs DCINENC1ENC2ST No.POWERRUNCPU-ESTOPRUNRIO ERR1 ERR2DI-RDI-

Seite 37 - STANDARDS

2. FAULT DIAGNOSIS 2.2 Troubleshooting II-4 2.2 Troubleshooting 2.2.1 Confirmation of trouble state Confirm "when", "when doing w

Seite 38 - II. MAINTENANCE MANUAL

2. FAULT DIAGNOSIS 2.2 Troubleshooting II-5 2.2.2 When in trouble If the system does not operate as planned or if there is any trouble in the ope

Seite 39 - 1.1 FX2N-80BMT-NC Card

2. FAULT DIAGNOSIS 2.2 Troubleshooting II-6 (1) Problems related to the power supply The power does not turn ON. Cause Remedy The door interl

Seite 40

2. FAULT DIAGNOSIS 2.2 Troubleshooting II-7 (2) Problems related to remote I/O unit (FCU6-DX561) If any of the following problems occur, all point

Seite 41 - 2.1 List of Unit LEDs

2. FAULT DIAGNOSIS 2.2 Troubleshooting II-8 The operation display "RUN" LED does not turn ON. Cause Remedy The RUN/STOP switch is se

Seite 42 - 2.2 Troubleshooting

2. FAULT DIAGNOSIS 2.2 Troubleshooting II-9 2.2.3 Behavior of independent faults The EN954-1 Category 3 machine system must be designed so that th

Seite 43 - 2.2.2 When in trouble

3. DAILY MAINTENANCE AND PERIODIC INSPECTION AND MAINTENANCE 3.1 Maintenance Tools II-10 3. DAILY MAINTENANCE AND PERIODIC INSPECTION AND MAINTENA

Seite 44

3. DAILY MAINTENANCE AND PERIODIC INSPECTION AND MAINTENANCE 3.2 Replacement Methods II-11 3.2 Replacement Methods 3.2.1 Cable If the cable is re

Seite 45

II. MAINTENANCE MANUAL 1. EXPLANATION OF MODULE FUNCTIONS ... II-1 1.1 FX2N-80BMT-

Seite 46

3. DAILY MAINTENANCE AND PERIODIC INSPECTION AND MAINTENANCE 3.2 Replacement Methods II-12 b) For a flat cable type connector with claws, open the

Seite 47

3. DAILY MAINTENANCE AND PERIODIC INSPECTION AND MAINTENANCE 3.2 Replacement Methods II-13 3.2.2 Unit Usually, the unit is installed on the electr

Seite 48 - MAINTENANCE

Revision history Revision Date of revision Revision details ∗ 00/12/01 First edition issued

Seite 49 - 3.2 Replacement Methods

BNP-B2302* (ENG)REMOTE I/O UNIT・FCU6-DX561008-165(0110) MEESpecifications subject to change without notice.Printed in Japan on recycled paper.MITSUBIS

Seite 50 - (2) Pull

I. CONNECTION MANUAL

Seite 51 - 3.2.2 Unit

1. OUTLINE I-1 1. OUTLINE This manual explains the items required for installing and connecting the remote I/O unit (FCU6-DX561). The FCU6-DX561

Seite 52

2. CONFIGURATION 2.1 System Configuration I-2 2. CONFIGURATION 2.1 System Configuration 0OPENCBUS 2CBUS 1MITSU BISHIMDS-B -SVJ2Remote I/O uni

Seite 53 - REMOTE I/O UNIT・FCU6-DX561

3. INSTALLATION 3.1 General Specification I-3 3. INSTALLATION 3.1 General Specification Unit name Remote I/O unit Type name FCU6-DX561 Durin