USER’S MANUALCENTRAL CONTROL SC-SL2N-EUSER’S MANUALCENTRAL CONTROL SC-SL2N-EENGLISHMANUEL DE L’UTILISATEURCOMMANDE CENTRALISEE SC-SL2N-EANWENDERHANDBU
– 9 –How to Make Settings for One UnitWhen managing an indoor unit with this central control without registering in any group, you can set individual
– 10 –<Changing an indoor unit number>To change the indoor unit number and continue with individual settings, after Step 5, repeat Steps 6 and 7
– 11 –4. Press the RESET button.The GROUP No. display section becomes blank.Example: “ 00”5. Press the SELECT ( or ) button to set the indoor un
– 12 –2. Press the SELECT ( or ) button to select the consecutive setting end unit number.3. Press the SET button.The consecutive setting end unit
– 13 –CENTER / REMOTE SettingSet whether to manage the indoor units being managed centrally using the central control or locally using the remote cont
– 14 –How to Enable / Disable Operations for Each Remote Control FunctionIt is possible to disable some operation functions (“temperature”, “operation
– 15 –How to Run / Stop AllThis runs or stops all the indoor units being managed. Method A < RUN > Press the RUN ALL button.All the indoor unit
– 16 –How to Run / Stop a GroupThis runs or stops a group. Method A < RUN > With the air conditioners stopped (RUN / ERROR display off), pres
– 17 –How to Run / Stop One UnitThis runs the selected indoor units.1 2 31. Press the ALL / GROUP / ONE button and select .The options are displayed
– 18 –How to Set Run DetailsThis sets the operation mode, temperature, fan speed, and louver direction.1 432 5 61. Press the ALL / GROUP / ONE button
– 1 –Table of contentsN Safety precaution ... 2N Names
– 19 –NoteThis operation is only possible for indoor units whose CENTER / REMOTE setting is “CENTER” or “CENTER and REMOTE”. This operation is disable
– 20 –3. Press the SELECT ( or ) button or a GROUP No. button to be set.To set the same program for all groups, select “88”.4. Press the SET butto
– 21 –2. How to Set “RUN and TEMP (temperature setting) at On time”1413, 151 to 12. Input the On time.Execute Steps 1 to 12 on Pages 19 to 20.13. Wi
– 22 –4. How to Set “STOP only at Off time” 9, 11101 to 8. Set the program number.Execute Steps 1 to 8 on Pages 19 to 20.9. With the On time (hour) s
– 23 –Z How to Set the Next Day of the Week1. In Step 7 or later, press the RESET button to return to Step 5 (with day of the week selection flash-
– 24 –4. Press the SET button.The contents of the program settings for all days of the week are copied. The copy destination group lights up for 2 se
– 25 –3. Press the SELECT ( or ) button or a GROUP No. button to select the group number to be set.To select all the groups, select “88”.4. Press
– 26 –2. Press the SET button.3. Press the SELECT ( or ) button or a GROUP No. button to select the group number to be set.To select all the group
– 27 –2. Press the SET button.3. Press the SELECT ( or ) button or a GROUP No. button to select the group number to be set.4. Press the SET butto
– 28 –How to Set an External Timer UnitAn off-the-shelf timer can be connected to this central control. Set the indoor units to be run by the external
– 2 –Safety precautionLBefore starting to use the central control, read these “Safety precaution” carefully to ensure proper operation of the central
– 29 –How to Set Demand UnitsDemand operation is not available in this central control.When a demand controller is connected to this central control,
– 30 –When Lights UpThis is displayed when an invalid value is set or an invalid button operation is attempted. Check the button opera-tion and unit
– 31 –When the Maintenance Display Lights Up or FlashesZ The time for periodic inspection has come.If there is one or more units being managed that
– 32 –When the Clean Filter Display Lights Up / FlashesZ This shows that it is time to clean the air filter. Clean the air filter.For details on how
– 33 –1. When the maintenance display and “BACKUP” are lit upThe outdoor unit is running in emergency mode and inspection is required. Please consu
– 34 –When the Running State of All or Some of the Indoor Units Set To Be Managed Is Not DisplayedZ This may happen due to some inadequacy of the co
– 35 –Z Emergency stop(The operations depend on the jumper line setting. For more information on jumper line settings, consult your dealer.)When the
– 36 –Error HistoryZ Error History Check Method (In Order of Occurrence)You can view the month, day, and time at which an error occurred for each ind
– 37 –Z How To Check the Error History for the Displayed Unit NumberYou can view the month, day, and time at which the most recent error occurred on
– 38 –L Have the following information available when requesting repairs.L Model nameL Installation dateL Problem status, as detailed as possibleL Ad
– 3 –Names and Functions of PartsThe diagram below shows the central control with its cover closed.You can open the cover downward by placing a hand o
AIR-CONDITIONING & REFRIGERATION SYSTEMS HEADQUARTERS3-1, Asahi, Nishibiwajima-cho, Kiyosu, Aichi, 452-8561, JapanMITSUBISHI HEAVY INDUSTRIES EURO
– 4 –CENTER / REMOTE displayDisplays which is in effect, the central control or the local remote controllers.PROGRAM SET displayDisplayed when a progr
– 5 –REMOTE CONTROL OPERATION ENABLE / DISABLE displayDisplays items for which remote control operation is disabled.HOLIDAY SET displayDisplayed when
– 6 –Setting the Time and DateProgram running uses the date and time set here as the standard.Please set the current date and time correctly.2, 4, 6,
– 7 –8. Press the SET button.The time hour display section flashes.9. Press the SELECT ( or ) button or a GROUP No. button to set the time (hour).W
– 8 –1. Press the MENU button and select .Each time you press this button, the display moves to the next step in the sequence in the diagram below.T